Critical care CPAP for EMS air or ground transport.

Airon’s MACS CPAP System is an easy-to-use, cost effective mask CPAP (Continuous Positive Airway Pressure) with a demand flow system. A calibrated knob sets the CPAP level and a switch selects 65% or 100% oxygen. Per run cost is less due to lower oxygen costs and affordable patient circuits. MACS CPAP System is designed for:

UNIQUE ADVANTAGES

  • Demand-flow CPAP automatically adjusts flow to meet changes in patient’s needs; maintaining airway patency and decreasing work of breathing
  • Lowest oxygen consumption on the market, providing the patient’s oxygen needs and increase run-time for transport
  • Accurate CPAP delivery with calibrated controls and built-in pressure gauge promotes monitoring of the patient
  • Lower cost of operation than disposable CPAP for busy EMS providers
  • More comfortable to the patient with a simple mask interface, no bulky CPAP valve at the patient interface
  • Fully pneumatic – No batteries or electricity needed

APPLICATIONS

MACS CPAP System is designed for:

• EMS ground and air transport

• ER

<
>

Benefits

For the patient

  • Provides non-invasive or invasive patient support
  • Low patient Work of Breathing (WOB) with peak flow of up to 140 L/min to meet patient needs
  • 100% or 65% to match patient oxygen requirements
  • Low-profile, easy-seal mask reduces facial pressure

For you, the Healthcare provider

  • Protection for the caregiver from patient exhalation using the bacteria / viral filter
  • Accurate CPAP delivery with calibrated controls and built-in pressure gauge ppromotes monitoring of the patient

For your budget

  • Lower cost of operation than disposable CPAP for busy EMS providers

Product videos

Additional information & Resources

Specifications

  • All pneumatic design and built tough; no batteries required
  • Calibrated CPAP control allows easy pressure adjustment to match patient requirements
  • Demand flow system with automatic flow triggering; peak flow to 140 L/min
  • Oxygen use only as needed to match patient effort
  • Pressure displayed on night viewable manometer
  • Classification according to MDD 93/42/EEC: IIb

Further Specifications

Gas supply
55 psi ± 15 psi oxygen 3.8 ± 1 bar)
Size
3.5” W x 8” D x 6.75” H (9 cm x 20 cm x 17 cm)
Weight
2.2 lbs. (1kg)

Meets international standards

  • ASTM F 920-85 Minimum Performance and Safety Requirements for Resuscitators Intended for use with Humans
  • ISO 10651-5:2006 Lung ventilators for medical use – Particular requirements for basic safety and essential performance – Part
  • 5: Gas-powered emergency resuscitators
  • IEC 60529:2001 Degrees of protection provided by enclosures, level IPX4

Control Settings

CPAP:
0 to 20 cm H2O (mbar)
Oxygen
100% or 65%
Regulatory Compliance

International Regulatory Compliance Information

Under regulatory compliance, our goal is to take steps to comply with relevant laws, policies, and regulations for medical device manufacturing and marketing Airon products. All Airon products are designed, manufactured, and supported based upon sound quality procedures. Every device is CE marked as well as USA FDA cleared.

Product Certification and Approvals

USA – FDA Free Sale Certificate – Certificate to Foreign Government

Canada – Medical Device Licenses
pNeuton ventilator license | patient circuit license

Europe – CE Marking certificates – Airon EC Certificate

Europe – Declarations of Conformity

USA – FDA 510(k) cleared

MACS 

MACS CPAP Product Brochure: English | Espanol | Deutsch | Francais

MACS CPAP Operator’s Manual: English | Espanol | Deutsch | Francais

MACS CPAP Operational Verification Procedure: English | Espanol | Deutsch | Francais

MACS CPAP Self-Guided Presentation: English | Espanol | Deutsch | Francais

MACS CPAP Introduction Video: English

MACS CPAP Preventative Maintenance Program: English

MACS CPAP Limited Warranty: English

Factory Rebuild Program: English

MACS CPAP Sample Protocol: English

MACS CPAP Oxygen Usage: English

MACS CPAP Environmental Testing: English

Real CPAP for EMS: English

Compliance with US Army Airworthiness Standards: English

Work of Breathing Comparison: English

NBC filter with pNeuton ventilators: English

Ordering Information

Ordering information for the MACS CPAP Ventilator , it’s accessories and more.

Customer Service Email:

[email protected]

20201 MACS CPAP System, device only

20011 MACS CPAP USA Startup Kit; everything you need to get started using your new ventilator.

Kit includes:

  • (1) MACS CPAP
  • (1) DISS high pressure oxygen hose, 8 foot, green
  • (1) MACS CPAP Travel Bag
  • (1) Box of 58011 patient circuits – 6 foot, large adult mask / head strap, single patient use, qty 10

20012 MACS CPAP International Startup Kit; everything you need to get started using your new ventilator.

Kit includes:

  • (1) MACS CPAP
  • (1) high pressure oxygen hose, 2.4, white, DISS connection on one end, customer specifies probe for other end (DIN, BOC, AGA or NIST)
  • (1) MACS CPAP Travel Bag
  • (1) Box of 58011 patient circuits – 1.8m, large adult mask / head strap, single patient use, qty 10

58001 Adult / pediatric, disposable, single use, 6 foot (1.8m), qty 15
58006 Adult / pediatric, disposable, single use, 6 foot (1.8m), expiratory filter, qty 15
58011 Adult / pediatric, disposable, single use, 6 foot (1.8m), large face mask / head strap, qty 10
58021 Adult / pediatric, disposable, single use, 6 foot (1.8m), large face mask / head strap, expiratory filter, qty 10


SAFETY NOTE: Only Airon manufactured patient breathing circuits are approved for use with the MACS CPAP System.

CPAP Mask, adult / pediatric, non-vented full face mask, short term use, qty 20
58208 Small
58202 Medium
58211 Large

HERO CPAP Mask, adult / pediatric, non-vented full face mask, single patient use, qty 20
58220 Small
58221 Medium
58222 Large

21040 Secure Pole Mount Bracket *Meets European EN 1789 requirements.
21041 Secure Bed Rail Mount Bracket *Meets European EN 1789 requirements.
21021 Travel Bag, MACS
21025 Protective Boot with shoulder strap, MACS

21002 Rigid Wall Test Lung, 1 liter

21051 Oxygen Regulator, MRI compatible, high pressure D / E cylinders
21073 Oxygen Cylinder, D size, green with toggle valve

Specialty Quick Connect Couplers
21100 Ohmeda Female, 3 inch hose
21101 Chemtron Female, 3 inch hose
21102 90 degree Male – Female DISS

Specialty Quick Connect Fittings
50347 Ohmeda Quick Connect
50348 Chemtron Quick Connect

97031 MACS CPAP System Operator’s Manual, English
97033 Spanish
97034 French
97035 German
Other languages available.
97021 User Resource CD

Browse our online catalog or read through our downloadable brochure

MACS in EMS World Magazine 2010: English

CPAP supplement JEMS 2011: English

CPAP supplement comments: English

Mask CPAP – State of Science: English

CPAP Bibliography: English

The pNeuton ventilators/CPAP systems are critical care devices designed for use by healthcare professionals under the direction of a physician or healthcare provider.